Medical Newborn Baby Care Equipment Hospital Infant Incubator
Product name: Newborn Baby Care Equipment
Item No.: JT-B1000
Features:
1. Servo Control Mode: air temperature;
2. Parameter Displaying: set temperature,air temperature, heat power rate;
3. Audible & Visual Alarms: powerfailure, sensor failure, higher & lower temp, air temperature override,fan failure, system failure;
4. >37℃Preset Mode: power failure reset memory, alarm silence, keypad lock, self-testfunction;
5. Hood with dual slope; 6 hand-ports;
6. RS-232 Output Connector (use for networksystem);
7. IV poles;
8. Protective guard rail;
9. Storage cabinets.
Main specification:
Specifications of hood
Mattress to Hood: 450 mm
Observation side of hood: Two incline
Operate port: 6 (2 Iris ports)
Tubing grommets: 4
Front access panel: 826×310 mm
Mattress Tray Size: 630×360 mm
Technical Specifications:
Power requirement ≤400VA
Temperature control mode: Air servo control
AirTemp Control Range: 20℃~37℃
Temperature override mode to: 20℃~39℃
Temperature fluctuation: ≤0.5℃
Mattress temperature uniformity: ≤0.8℃
Temperature rise time: ≤45 min
Noise level within hood environment: ≤55dB
Alarms
Power failure alarm
Fan failure alarm
Sensor failure alarm
High air temperature alarm: +3.0℃
Low air temperature alarm: -3.0℃
Over air temperature alarm: ≤38.0℃; ≤40.0℃
System failure alarm
Alarm silence function
Operational condition
Environment temperature: +20℃~+30℃
Environment relative humidity: 5%~99%
Environment air velocity of flow: <0.3m/s
Others
Infant bed tilt adjusting ±10° step-less
Mattress tray Max. load 10kg
Transfusion pole Max. load 2kg
Cabinet Max. load 6kg
Advantage of Our Company
1. Professional medical products manufacture for more than 10 years
2. High quality with competitive price
3. Independent Design and Outstanding Sales Team
4. Large Supply Ability
5. Excellent after-Sales service
Product Categories : Hospital Equipment > Incubator/Radiant Warmer
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.